FAQ for Door Lock Switch Repair
Q: What is the removal procedure for the Power Door Lock Switch?
A:
Remove the door handle bezel. Release the retaining tabs for the power door lock switch from the door handle bezel. Disconnect the electrical connector from the power door lock switch.
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for the front door system locking module bolt?
A:
The recommended torque is 10 N.m (89 lb in).
By BobGM Specialist
01/11/2022 Q: What is the installation procedure for the Power Door Lock Switch?
A:
Install the power door lock switch to the door handle bezel. Connect the electrical connector to the power door lock switch. Install the door handle bezel.
By BobGM Specialist
01/11/2022 Q: What should be done before servicing the Locking System Module?
A:
You should remove the front door water deflector.
By BobGM Specialist
01/11/2022