Part Description: 2004 Cadillac SRX Direct Ignition Coil
Vehicle Fitment
2004 Cadillac SRX | All Trims | 8 Cyl 4.6L
FAQ for Ignition Coil Repair
Q: What is the removal procedure for the Bank 1 ignition coils?
A:
The procedure is to turn the ignition OFF and remove the following: the engine cover, the intake manifold, the ignition coil electrical connector(s), the ignition coil bolt(s), and the ignition coil(s).
By Bob
GM Specialist
01/11/2022
Q: What is the removal procedure for the bank 2 ignition coil(s)?
A:
The procedure is to turn the ignition OFF and remove the following: the engine cover, the intake manifold, the ignition coil electrical connector(s), the ignition coil bolt(s), and the ignition coil(s).
By Bob
GM Specialist
01/11/2022
Q: What is the recommended torque when installing the ignition coil bolt(s)?
A:
You can tighten the ignition coil bolt(s) to 10 N.m (89 lb in).
By Bob
GM Specialist
01/11/2022
FAQ for Other Repair Info
Q: What is the removal procedure for the Bank 1 knock sensor (KS)?
A:
The procedure is to turn the ignition OFF, raise the vehicle, reposition the wiring harness heat shield, remove the Knock Sensor (KS) electrical connector, remove the KS bolt and remove the KS.
Q: What is the recommended torque when installing the wire harness retainer and bolt to the side of the ECM bracket?
A:
You can tighten the wire harness retainer bolt to 23 N.m (17 lb-ft).