The procedure is to remove the air cleaner outlet assembly, drain the cooling system, reposition the radiator vent inlet hose clamp at the coolant air bleed pipe fitting, remove the radiator vent inlet hose from the coolant air bleed pipe fitting, reposition the radiator inlet hose clamp at the
Water Pump, remove the radiator inlet hose from the water pump, reposition the radiator inlet hose and vent inlet hose out of the way, remove the accessory drive belt, reposition the radiator outlet hose clamp at the water pump, remove the radiator outlet hose from the water pump, reposition the outlet hose out of the way, reposition the heater inlet hose clamp at the water pump, remove the heater inlet hose from the water pump, reposition the inlet hose out of the way, and then remove the water pump bolts and the water pump and gaskets.