FAQ for Hvac Heater Blend Door Actuator Repair
Q: How do you install the Mode Actuator Replacement - Lower?
A:
You need to install the lower mode actuator, press the lower mode actuator on until you hear tabs engage, and install the I/P carrier.
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for the air temperature actuator retaining screws?
A:
The recommended torque is 1.9 Nm (17 lb in).
By BobGM Specialist
01/11/2022 Q: How do you install the Auxiliary Mode Valve Actuator?
A:
You need to install the auxiliary mode actuator, install the retaining screws to the auxiliary mode actuator, and install the auxiliary HVAC module assembly.
By BobGM Specialist
01/11/2022 Q: How do you install the Mode Actuator - Upper?
A:
You need to hook the upper mode door actuator to the mode door lever, install the upper mode actuator, press the upper mode actuator on until you hear tabs engage, connect the vacuum line to the upper mode door actuator, and reposition and install the I/P carrier.
By BobGM Specialist
01/11/2022 Q: How do you install the Temperature Valve Actuator?
A:
You need to install the air temperature actuator to the heater assembly, the air temperature actuator retaining screws, and connect the air temperature actuator electrical connector.
By BobGM Specialist
01/11/2022 Q: What kind of special tools will be used in the replacement of the Recirculation Actuator?
A:
J39400-A Electronic Halogen Leak Detector.
By BobGM Specialist
01/11/2022 Q: What is the removal procedure for the Auxiliary Temperature Valve Actuator?
A:
Remove the left rear quarter trim panel, disconnect the electrical connector from the air temperature actuator, and remove the retaining screws from the air temperature actuator, and the air temperature actuator.
By BobGM Specialist
01/11/2022 Q: What is the removal procedure for the Defroster Valve Actuator?
A:
The procedure is to remove the I/P upper trim pad, disconnect the vacuum hose from the defrost actuator, depress the clip, and remove the defrost actuator from the heater assembly.
By BobGM Specialist
01/11/2022 Q: What is the removal procedure for the Mode Actuator - Upper?
A:
The procedure is to rotate the instrument panel (I/P) carrier out and downward, disconnect the vacuum hose from the upper mode actuator, release the tabs from the upper mode actuator, unhook the actuator from the upper mode door lever, and remove the upper mode actuator.
By BobGM Specialist
01/11/2022 Q: What is the recommended torque when installing the evaporator outlet hose and retaining nuts?
A:
The recommended torque is 18 Nm (13 lb-ft).
By BobGM Specialist