FAQ for Fuel Sending Unit Repair
Q: What tools aren't recommended when working on fuel gauge sender?
A:
Do NOT use impact tools. A significant force will be required to release the lock ring. The use of a hammer and screwdriver is not recommended.
By OmarGM Specialist
26/12/2021 Q: How do I know if my lock rings need replacement?
A:
Place the lock ring on a flat surface. Measure the clearance between the lock ring and the flat surface. If the warpage is less than 0.41 mm the lock ring does not require replacement. If the warpage is greater than 0.41 mm then replace the lock ring.
By BobGM Specialist
21/12/2021 Q: How many fuel pipes will I need to disconnect?
A:
You will need to disconnect two fuel pipes.
By BobGM Specialist
21/12/2021 Q: How many module connectors will I have to disconnect?
A:
You will need to disconnect two module connectors.
By OmarGM Specialist
16/12/2021