FAQ for Hvac Control Module Repair
Q: What is the recommended torque for the Left Air Temperature Actuator Screw?
A:
The recommended torque is 2 N.m (18 lb in).
By BobGM Specialist
01/11/2022 Q: What will need to be done before replacing the Mixer Valve?
A:
First, you need to remove the air distribution case. Then, please disconnect all the electrical connectors from the components associated with the HVAC module. Finally, you should remove any components associated with splitting the air distribution case.
By BobGM Specialist
01/11/2022 Q: What will need to be done before replacing the Heater and Air Conditioning Control Temperature Lever (Left Side)?
A:
First, you need to remove the left side I/P insulator. Then, please disconnect all the electrical connectors from the components associated with the left air temperature actuator.
By BobGM Specialist
01/11/2022 Q: What will need to be done before replacing the Defroster Valve?
A:
First, you need to remove the air distribution case. Then, please disconnect all the electrical connectors from the components associated with the HVAC module. Finally, you should remove any components associated with splitting the air distribution case.
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for the Right Air Temperature Actuator Screw?
A:
The recommended torque is 2 N.m (18 lb in).
By BobGM Specialist
01/11/2022 Q: What will need to be done before replacing the Mode Control Cable?
A:
You need to remove the front floor console, the front floor console rear compartment, and the left front floor console side panel and disconnect any electrical connectors from the front floor console.
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for the HVAC control module screw?
A:
The recommended torque is 2Nm(18 lb in).
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for the Blower Motor Control Processor Screw?
A:
The recommended torque is 9Nm(80 lb in).
By BobGM Specialist
01/11/2022 Q: How to replace the Vent Valve?
A:
You need to re-program all HVAC actuators and control modules associated with the heater and A/C control wiring harness.
By BobGM Specialist
01/11/2022 Q: How to replace the Defroster Valve?
A:
You need to re-program all HVAC actuators and control modules associated with the heater and A/C control wiring harness.
By BobGM Specialist
01/11/2022 See more FAQs (10)