You need to remove the fuel tank, disconnect the fuel pump fuel feed line quick connect fitting from the fuel tank module and evaporative emission (EVAP) canister vent front pipe quick connect fitting from the fuel tank module, reposition the fuel pump fuel feed line and the EVAP canister vent front pipe out of the way, disconnect the fuel sender wiring harness electrical connector from the fuel tank pressure sensor and the fuel sender wiring harness electrical connector from the fuel tank module, install the J 45722 to the fuel tank module lock ring, rotate the lock ring counterclockwise unlocking the fuel tank module lock ring, remove the J 45722 and the fuel tank module lock ring, raise the module, tilt the module towards the lower front corner of the fuel tank to allow the level sensor float arm to clear the tank opening, remove the module from the fuel tank, discard the fuel in the module reservoir bucket into an approved container, and then remove and discard the fuel tank module seal and the fuel level sensor.
By BobGM Specialist
01/11/2022