Contact Us Live Chat or 1-888-220-8330
Search Bar
Search by Part Number or Keywords
  • My Garage
  • My Account
  • Cart
  • Body & Mirrors
  • Chassis & Brakes
  • Engine & Drivetrain
  • Electrical & Lighting
Help Center
< Back ×
Replacement and OEM Parts for 2007 Chevrolet Monte Carlo Secondary Air Injection Check Valve

2007 Chevrolet Monte Carlo Secondary Air Injection Check Valve

My Vehicle Change Vehicle
2007 Chevrolet Monte Carlo
Change Vehicle
Vehicle Options
We need more information about your vehicle to make a correct determination of fitment
< Back to View All
Emission Control
  • Department
  • Brands
  • Prices

1 Product found

3 Q&A for Secondary Air Injection Check Valve Repair
Show Item:
  • 30
  • 60
  • 90
Sort by:
Recommended
Filter
Sort
View by
  • Dorman OE Solutions Secondary Air Injection Check Valve for 2007 Chevrolet Monte Carlo - 911-153

    Dorman® OE Solutions Secondary Air Injection Check Valve for 2007 Chevrolet Monte Carlo

    PartNumber: 911-153
    Product Specifications
    • Notes: 2ndary Air Inj Shutoff & Check Valve; Packaging Type: Box
    • Color: Natural
    • Inlet Size: 0.91"
    • Material: Cast Aluminum
    • Maximum Pressure Rating: 50 PSI
    • OE Part Number: 12619123, 12659290
    • Outlet Size: 0.71"
    • UPC: 019495490982
    • Valve type: Solenoid
    • Working Temperature Range: -40C To 75C
    • Part Description: 2007 Chevrolet Monte Carlo OE Solutions Secondary Air Injection Check Valve
    More Info
    Vehicle Fitment
    • 2007 Chevrolet Monte Carlo | All Trims | 6 Cyl 3.5L
    $202.39

FAQ for Secondary Air Injection Check Valve Repair

Q: How do I install the Secondary Air Injection Shutoff and Check Valve?
A:
Start with installing a new gasket onto the air pipe studs. Before installing the air check, be sure that it is properly placed. Next, install the air check valve bolts. Lift the vehicle. Lastly, install the air check valve nuts.
By Omar
GM Specialist
16/03/2022
Q: How do I remove the Secondary Air Injection Shutoff and Check Valve?
A:
Start with removing the exhaust crossover pipe, then disconnect the secondary air feed tube connect fitting from the air shutoff/check valve. Remove the bolt attaching the heater inlet/outlet pipe bracket. Next, you'll need to disconnect the engine wiring harness electrical connector from the AIR shutoff/check valve. Lift vehicle. Remove the nuts attaching the valve then lower the vehicle and remove the bolts attaching the valve. Lastly, remove the valve and gasket.
By Omar
GM Specialist
15/03/2022
Q: What is the recommended bolt torque for the air check valve bolts and nuts?
A:
The recommended bolt torque for the bolts is 50 Nm (37 LB-FT) and 10 Nm (89 LB IN) for the valve nuts.
By Bob
GM Specialist
10/03/2022