Q: What is the removal procedure for the starter motor (DOHC)?
A:
The procedure is to disconnect the negative battery cable and remove the following: the upper and the lower starter mounting bolts, the starter solenoid nuts to disconnect the electrical cable, and the starter assembly.
By Bob
GM Specialist
02/11/2022
Q: What is the recommended torque when installing the upper and the lower starter mounting bolts?
A:
You can tighten the starter mounting bolts to 43 N.m (32 lb-ft).
By Bob
GM Specialist
02/11/2022
Q: What is necessary when the starter motor is disassembled and the solenoid is replaced?
A:
It is necessary to check the pinion clearance.
By Bob
GM Specialist
02/11/2022
Q: What is the purpose of completing the testing as quickly as possible?
A:
The purpose is to prevent overheating and damaging the solenoid.
By Bob
GM Specialist
02/11/2022
FAQ for Other Repair Info
Q: What should you use to front-probe terminals?
A:
You should always use the J 35616-B Connector Test Adapter Kit or the J 42675 Flat Wire Probe Adapter Kit for front-probe terminals.
Q: What is the recommended torque when installing the generator through bolts?