FAQ for A/C System Seal Kit Repair
Q: What should be noted when removing the Sealing Washer?
A:
You must not reuse the sealing washer.
By BobGM Specialist
28/10/2022 Q: What should be noticed while removing the O-Ring?
A:
You shall cap or tape the open A/C refrigerant components immediately to prevent system contamination.
By BobGM Specialist
28/10/2022 Q: What should be learned about while installing the Sealing Washer?
A:
After tightening the A/C components, there should be a slight sealing washer gap of approximately 1.2 mm (3/64 in) between the A/C line and the A/C component.
By BobGM Specialist
28/10/2022 Q: What should be noted when installing the O-Ring?
A:
You must not allow any of the mineral base 525 viscosity refrigerant oil on the new O-ring seal to enter the refrigerant system.
By BobGM Specialist
28/10/2022 Q: What should be learned about before servicing the Compressor Sealing Washers?
A:
If you use the correct washers, there should be a space of 1.2 mm (0.047 in) between the suction/discharge hose block and the compressor rear head.
By BobGM Specialist
28/10/2022