FAQ for Hvac Heater Blend Door Actuator Repair
Q: What is the removal procedure for the right air temperature actuator?
A:
You need to remove the I/P carrier, disconnect the electrical connector from the right air temperature actuator, and remove the screws from the right air temperature actuator and the right air temperature actuator from the HVAC module assembly.
By BobGM Specialist
01/11/2022 Q: What is the recommended bolt torque for the screws to the center console duct?
A:
The recommended bolt torque is 1.6 Nm (14 lb in).
By BobGM Specialist
01/11/2022 Q: What is the removal procedure for the recirculation actuator?
A:
You need to remove the air distribution duct, disconnect the electrical connection from the recirculation actuator, and the recirculation actuator retaining screws and the recirculation actuator.
By BobGM Specialist
01/11/2022 Q: What is the recommended bolt torque for the screws to the recirculation actuator?
A:
The recommended bolt torque is 2 Nm (18 lb in).
By BobGM Specialist
01/11/2022 Q: What is the recommended bolt torque for the mode actuator mounting screw?
A:
The recommended bolt torque is 1.6 Nm (14 lb in).
By BobGM Specialist
01/11/2022 Q: What is the recommended bolt torque for the screws to the left air temperature actuator?
A:
The recommended bolt torque is 2 Nm (18 lb-ft).
By BobGM Specialist
01/11/2022 Q: What is the recommended bolt torque for the auxiliary air temperature actuator retaining screws?
A:
The recommended bolt torque is 1.6 Nm (14 lb in).
By BobGM Specialist
01/11/2022 Q: What is the removal procedure for the mode actuator?
A:
You need to remove the floor air outlet duct extension from the floor duct, the center console, the screws from the center console duct, and the center console duct, and disconnect the electrical connection from the mode actuator. You also need to remove the mode actuator mounting screws from the HVAC module and the mode actuator as an assembly with the actuator cam.
By BobGM Specialist
01/11/2022 Q: What is the recommended bolt torque for the screws to the right air temperature actuator?
A:
The recommended bolt torque is 2 Nm (18 lb in).
By BobGM Specialist
01/11/2022 Q: What is the removal procedure for the left air temperature actuator?
A:
You need to remove the I/P insulator panel, disconnect the electrical connector from the left air temperature actuator, and remove the screws from the left air temperature actuator and the left air temperature actuator from the HVAC module assembly.
By BobGM Specialist
01/11/2022 See more FAQs (7)