FAQ for Secondary Air Injection Check Valve Repair
Q: What is the installation procedure for the Secondary Air Injection Shut-Off Valve-Bank 2?
A:
The procedure is to position the secondary air injection (AIR) shut-off valve (2) with a new outlet pipe gasket to the outlet pipe and bracket, connect the intermediate hose and the electrical connector, and install the air cleaner assembly.
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for the bolts securing the AIR shut-off valve to the cam cover?
A:
It is 9 N.m (80 lb in).
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for the nuts securing the outlet pipe to the exhaust manifold?
A:
It is 9 N.m (80 lb in).
By BobGM Specialist
01/11/2022 Q: How to remove/install the AIR Shut-Off Valve Outlet Pipe-Bank 1?
A:
You shall install the bank 1 AIR outlet pipe, new gasket, and the bank 1 AIR check valve.
By BobGM Specialist
01/11/2022 Q: What is the removal procedure for the AIR Shut-Off Valve Outlet Pipe-Bank 1?
A:
The procedure is to remove the bank 1 secondary air injection (AIR) check valve and the bank 1 AIR outlet pipe.
By BobGM Specialist
01/11/2022 Q: What is the removal procedure for the Secondary Air Injection Shut-Off Valve-Bank 2?
A:
The procedure is to remove the air cleaner assembly, disconnect the electrical connector and the intermediate hose, and remove the AIR shut-off valve.
By BobGM Specialist
01/11/2022 See more FAQs (1)