The procedure is to remove the pump reservoir cap, fill the pump reservoir with fluid to the full cold level, attach J 43485 to J 35555 or equivalent, place J 43485 on or in the pump reservoir filler neck, apply a vacuum of 68 kPa (20 inch Hg) maximum, remove the J 43485 and the J 35555, reinstall the pump reservoir cap, and start the engine.