FAQ for A/C Accumulator Repair
Q: What tools are required to replace the accumulator assembly, spacer plate, and gaskets?
A:
J25025-5 M6 X 1.00 Alignment Pin and J36850 Transjel(R).
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for connecting the accumulator to the evaporator.?
A:
The recommended torque is 41 N.m (30 lb-ft).
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for tightening the accumulator housing bolts?
A:
The recommended torque is 11 Nm (97-inch lbs.).
By BobGM Specialist
01/11/2022 Q: What tools are required to replace the accumulator HVAC?
A:
J38042 Dual O-Ring Tube Separator.
By BobGM Specialist
01/11/2022 Q: How do I remove the accumulator HVAC?
A:
You should disconnect the negative battery cable and recover the refrigerant. Then you should disconnect the electrical connectors and remove the pressure cycling switch. Lastly, you should disconnect the hose assembly from the accumulator.
By BobGM Specialist
01/11/2022 Q: What is the recommended torque for installing the accumulator bracket screw?
A:
The recommended torque is 6 N.m (53 lb in).
By BobGM Specialist
01/11/2022 Q: What should be noticed in removing the accumulator assembly, spacer plate, and gaskets?
A:
You should check the solenoid screens on the spacer plate for damage or debris and replace the solenoid screens if necessary.
By BobGM Specialist
01/11/2022 See more FAQs (2)