FAQ for A/C Hose Repair
Q: What special tools will be used in the service of the Heater and A/C Pipe-Auxiliary?
A:
The J 41425 A/C Line Repair Kit will be used in the service of the Heater and A/C Pipe - Auxiliary.
By BobGM Specialist
28/10/2022 Q: How to remove the Compressor Hose Assembly?
A:
You should remove the air cleaner cover and duct assembly, the refrigerant, the compressor line block fitting, and the compressor condenser hose assembly.
By BobGM Specialist
28/10/2022 Q: How to remove the Accumulator Tube?
A:
You should disconnect the suction line and remove the following parts: the air cleaner cover and duct assembly, the refrigerant, the suction line fitting, the suction line bracket, and the O-rings.
By BobGM Specialist
28/10/2022 Q: What is the recommended torque for the compressor line block fitting at the condenser?
A:
The recommended torque is 16 N.m (11 LB-FT).
By BobGM Specialist
28/10/2022 Q: What should be noted when servicing the Hose/Line HVAC?
A:
You should be careful not to bend the flexible hose line to a radius of fewer than 4 times the diameter of the hose.
By BobGM Specialist
28/10/2022 Q: What is the recommended torque for the liquid line fitting at the condenser?
A:
The recommended torque is 27 N.m (20 LB-FT).
By BobGM Specialist
28/10/2022 Q: What should you do before disconnecting the fitting in the refrigeration system?
A:
You should discharge all of the Refrigerant-134a.
By BobGM Specialist
28/10/2022 Q: What is the recommended torque for the liquid line fitting at the block fitting?
A:
The recommended torque is 16 N.m (12 LB-FT).
By BobGM Specialist
28/10/2022 Q: What is the recommended torque for the liquid line fitting at the orifice?
A:
The recommended torque is 27 N.m (20 LB-FT).
By BobGM Specialist
28/10/2022 Q: What is the recommended torque for the suction line at the block fitting bolt?
A:
The recommended torque is 16 N.m (12 LB-FT).
By BobGM Specialist
28/10/2022 See more FAQs (10)